LEVEX
MF-LT Series
Continuous Level Transmitter
Continuous Level Transmitter
The MF-LT Series Level Transmitter delivers high-accuracy continuous level monitoring for seamless integration with PLCs, SCADA systems, and control panels. Utilizing stable resistance ladder technology with magnetic float tracking, this transmitter provides real-time analog output for precise tank management.
Key Features
- Continuous Analog Output: Stable 4-20mA or 0-10V signal
- High Resolution: 1cm or 2cm measurement increments
- SCADA/PLC Ready: Standard industrial outputs for easy integration
- Robust Construction: SS304/316 or PTFE wetted materials
- Wide Measurement Range: Up to 3000mm measurement span
✓ Industry 4.0 Ready
The MF-LT Series integrates seamlessly with modern industrial automation systems, providing reliable data for predictive maintenance, inventory management, and process optimization.
Technical Specifications
| Parameter | Stainless Steel (std.) | PVC | TEFLON |
|---|---|---|---|
| Detection Method | Magnetic Float with Precision Resistance Ladder | ||
| Wetted Material | Stainless Steel | PVC | TEFLON |
| Probe Length | 200~4000mm | 200~4000mm | 200~2000mm |
| Process Connection | NPT 2.5" (std.) / Flange (std.) | ||
| Enclosure | Aluminium, TEFLON, SS, Plastic | ||
| Supply Voltage | 12-24VDC (for 4-20mA) / 16-24VDC (for 0-10V) | ||
| Output Signal | 4–20 mA / 0–10 V / Resistance | ||
| Resolution Options | 1 cm or 2 cm (Resistance output: 1.3cm only) | ||
| Repeatability | ±1 cm or ±2 cm typical (same value as resolution) | ||
| Response Time | <500 mSec | ||
| Zero/Span Set | Using a multi-turn trim POT | ||
| Process Temperature | –20 °C to +80 °C | –20 °C to +60 °C | –20 °C to +80 °C |
| Ambient Temperature | –20 °C to +60 °C | ||
| Storage Temperature | –40 °C to +60 °C | ||
| Humidity | 0–95 % RH (non-condensing) | ||
Typical Applications
Chemical Processing
Reactor vessels, storage tanks, day tanks
Water Treatment
Clarifiers, settling tanks, storage reservoirs
Oil & Gas
Separator vessels, crude storage, product tanks
Food & Beverage
Process tanks, ingredient storage, CIP systems
Pharmaceutical
Buffer tanks, API storage, clean utilities
Power Generation
Cooling systems, condensate tanks, chemical feed
Output Configurations
| Output Type | Specifications | Typical Use |
|---|---|---|
| 4-20mA (2-wire) | Loop powered, 12-30VDC supply, Max 500Ω load | Standard industrial automation, long cable runs |
| 0-10VDC | 3-wire, 24VDC supply, Min 10kΩ load | Building automation, short distances |
| 0-5VDC | 3-wire, 24VDC supply, Min 10kΩ load | Legacy systems, analog controllers |
| HART Protocol | 4-20mA with digital overlay | Advanced diagnostics and configuration (Optional) |
Integration Benefits
Why Choose MF-LT for Process Control?
- Real-Time Monitoring: Continuous data stream for accurate inventory tracking
- Alarm Generation: Programmable high/low level alarms in your control system
- Pump Control: Automated pump start/stop based on level thresholds
- Data Logging: Historical trend analysis for process optimization
- Remote Monitoring: SCADA integration for centralized control
- Reduced Waste: Precise level control prevents overfills and shortages
⚙️ Request a Quote for MF-LT Level Transmitter
Fill out the form below with your tank specifications and requirements. Our technical team will respond with a detailed quote within 24 hours.
Upgrade Your Tank Monitoring System
Ready to integrate continuous level measurement into your process control system? Our team will help you specify the right MF-LT configuration for your application.
Request a Quote View All LEVEX Products